Search results
Jump to navigation
Jump to search
Create the page "Quantro" on this wiki! See also the search results found.
- Quantar (section Quantar/Quantro info)Manual 68P81088E90-G - this is the full service manual for the Quantar/Quantro and AstroTac Quantar RSS Manual R14.10.00 Quantar RSS Manual R14.13.00 a28 KB (2,928 words) - 00:11, 4 May 2024
- need the Aux Power supply module CLF1580, or in a pinch you can use the quantro IPA which does the same thing. The main power supply supports 5v and 14v9 KB (1,026 words) - 14:04, 26 February 2024
- IPA module. Quantro Backplane TRN7688A Service Manual Excerpt Quantro Backplane TRN7688A Connectors Quantro Backplane TRN7688A Pinouts Quantro BackPlane2 KB (159 words) - 07:57, 6 April 2019
- Like all the other preselectors, these are used from the Quantar/Quantro through the MTR2000/MTR3000 stations. VHF R1 132-154 MHz TFD6511 CLD1210 VHF R2343 bytes (42 words) - 09:31, 2 May 2024
- Subject: QUANTAR/QUANTRO RELATED ISSUES WHEN USED IN MIXED STATION SYSTEMS. 1) RECEIVER VOTING SYSTEM ISSUE. SYMPTOM: A QUANTAR/QUANTRO STATION WILL NOT2 KB (225 words) - 06:10, 28 March 2019
- 31, 1995 Subject: QUANTAR and QUANTRO ISSUES. MODELS AFFECTED: T5365 and T5367 ITEMS #1 THRU #3 - All QUANTAR and QUANTRO STATIONS in CONVENTIONAL SYSTEM10 KB (0 words) - 06:07, 28 March 2019
- EXPIRES : N/A SUBJECT: QUANTAR/QUANTRO MODULATION COMPENSATION PROCEDURE INFO. MODELS AFFECTED: T5365A QUANTAR/QUANTRO SYSTEMS AFFECTED: SMARTZONE 3.02 KB (278 words) - 05:58, 28 March 2019
- 1996 (708) 576-0180 EXPIRES : N/A MODEL AFFECTED: T5365A Subject: QUANTAR/QUANTRO EQUIPMENT ISSUES. 1) WHEN INSTALLING STATION CONTROL BOARD AND WIRELINE9 KB (0 words) - 06:12, 28 March 2019
- AUGUST, 2000 EXPIRES: N/A SUBJECT: Quantar/Quantro enhanced code plug conditioning MODELS AFFECTED: Quantar/Quantro stations, (T5365A) Quantar Sattellite Receivers3 KB (433 words) - 06:30, 28 March 2019
- EXPIRES: N/A SUBJECT: QUANTAR/QUANTRO MAY NOT RECOVER UPON POWER INTERRUPTION OR POWER LOSS MODELS AFFECTED: QUANTAR / QUANTRO (T5365A)4 KB (475 words) - 05:57, 28 March 2019
- DECEMBER, 97 EXPIRES: N/A SUBJECT: QUANTAR/QUANTRO CONTINUOUS RESETS WITH SHORT POWER LOSS MODELS AFFECTED: T5365A QUANTRO /QUANTAR/ INTELLI REPEATER SYSTEMS AFFECTED:1 KB (0 words) - 06:22, 28 March 2019
- EXPIRES: N/A SUBJECT: QUANTAR / QUANTRO, ASTRO-ONLY, REFERENCE MODULATION ALIGNMENT PROBLEM. MODELS AFFECTED: T5365A QUANTAR / QUANTRO EQUIPPED WITH MODEMS. SYSTEMS2 KB (0 words) - 06:26, 28 March 2019
- EXPIRES: 9/30/99 SUBJECT: QUANTAR/QUANTRO STATIONS DRIFTING OFF FREQUENCY MODELS AFFECTED : All T5365A QUANTAR/QUANTRO STATIONS THAT INCLUDE THE UHSO (ULTRA4 KB (0 words) - 06:24, 28 March 2019
- N/A Subject: QUANTAR/QUANTRO BASE & REPEATER STATIONS NOT GENERATING BSI (BASE STATION IDENTIFICATION) MODELS AFFECTED: T5365A QUANTRO/QUANTAR STATIONS SYSTEMS2 KB (0 words) - 06:16, 28 March 2019
- DATE: SEPTEMBER, 1997 (847) 576-0180 EXPIRES : 9/1/98 SUBJECT: QUANTAR /QUANTRO 6809 TRUNKING MODULATED AUDIO MODELS AFFECTED : T5365A WITH X989 OR3 KB (0 words) - 05:50, 28 March 2019
- S-0044 APC # 509 DATE: JULY, 2001 EXPIRES: NA SUBJECT: Enhanced Quantar/Quantro Base Station Transmit Deviation Procedure for ASTRO Simulcast Systems. SYSTEMS14 KB (1,142 words) - 06:30, 28 March 2019
- 60196 Date: OCTOBER, 1996 (847)576-0180 EXPIRES : NA Subject: QUANTAR/QUANTRO BASE/REPEATER STATION WILDCARD OUTPUT COMPATIBILITY ISSUE MODELS AFFECTED:2 KB (0 words) - 06:15, 28 March 2019
- REPEAT FREQUENCY MODELS AFFECTED: 6809 TRUNKED OR INTELLIREPEATER QUANTAR/ QUANTRO BASE STATIONS REFERENCE NUMBERS: DDTS# TRKrs03006; FRB # 287 . ISSUE : DROPPED2 KB (0 words) - 06:18, 28 March 2019
- KEY-UPS ON CHANNELS CONFIGURED FOR PL/DPL MODELS AFFECTED: T5365A QUANTAR/QUANTRO SYSTEMS AFFECTED: CONVENTIONAL WITH TRC CONSOLE AND/OR TRC C0MPARATOR SYMPTOM:3 KB (302 words) - 05:55, 28 March 2019
- REPORTS DIGITAL METERED VOLTAGES INCORRECTLY. MODELS AFFECTED: T5365A QUANTAR/QUANTRO, T5367A QUANTAR RECEIVER (Models Affected were built between 5/01/99 and22 KB (389 words) - 05:56, 28 March 2019