SERVICE AND REPAIR NOTES Bulletin SRN # S-0012
SYMPTOM: Due to an error in manufacturing of EMI cover in the power supply, it is possible that the cover could deflect or pierce the insulation of the input AC line and neutral conductors. Should the EMI cover pierce the input AC power conductor insulation, depending on which conductor (line or neutral) contacts the shield, either a branch circuit breaker will trip or a small current can flow into safety earth ground (green wire). If current flows in the neutral to earth ground path, some erratic station operation could occur, such as degraded hum and noise. WARNING: There is a risk of shock in a non-code-wired facility and/or improper grounded station. CAUSE: A correctly designed EMI cover is slotted to avoid contact with the AC input and does not have RFI "fingers" above the AC conductors. On the incorrectly manufactured covers that are the subject of this Bulletin, the "fingers" are above the insulated AC conductors, and these "fingers" could come in contact with the AC mains power. Incorrectly manufactured EMI covers were installed in Quantar, Data Basestations and Comparator's AC power supplies. Both covers have the same part numbers (pt. no. 15D85034U11). The only way to identify the suspect covers is to visually inspect the cover, refer to samples below.
RESOLUTION: Defective EMI covers MUST be replaced. SUSPECT STATION IDENTIFICATION: Defective EMI covers could possibly exist in some but perhaps not all the stations with the serial numbers listed below. It will be necessary to inspect each unit to determine if the cover needs to be replaced. SERIAL NUMBERS OF STATIONS MANUFACTURED AND FIELD REPLACEMENT UNITS (FRUs) WITH POSSIBLE DEFECTIVE EMI COVERS SRN # S-000X 225CZX0036 THROUGH 225CZX0036 225CAHXXXX THROUGH 225CAMXXXX 360CAKXXXX THROUGH 360CAMXXXX 448CAFXXXX THROUGH 448CAMXXXX 509CAHXXXX THROUGH 509CAMXXXX 525CAHXXXX THROUGH 525CAMXXXX 537CAHXXXX THROUGH 537CAMXXXX 590CAFXXXX THROUGH 590CAMXXXX 675CAHXXXX THROUGH 675CAMXXXX 677CAKXXXX THROUGH 677CAMXXXX 680CAKXXXX THROUGH 680CAMXXXX 732CAHXXXX THROUGH 732CAMXXXX 743CAMXXXX THROUGH 743CAMXXXX IDEN 547CAK4446, 547CAK4448, AND 547CAK5680 FRUs CAE000FHBK, CAE000FL2N, CAE000D1DX, CAE000FTHS, CAE000FTHC, CAE000F33Y, CAE0009CJ2, and CAE0009CJ3 -------------------------------------------------------- PROCEDURE TO IDENTIFY, INSPECT AND REPLACE EMI COVER:
Authorized Motorola Service Shops will be allowed 15 minutes labor time per station to inspect, and if required install the new EMI covers, plus travel. Servicers should submit a standard labor warranty claim form and make reference to this bulletin number. |