LAND MOBILE PRODUCT SECTOR 1301 E. ALGONQUIN RD. SCHAUMBURG, IL. 60196 (847) 576-0180 PSB # 868 APC # 409, 448, 482, 509 DATE: February, 1999 EXPIRES: N/A SUBJECT: QUANTAR / QUANTRO, ASTRO-ONLY, REFERENCE MODULATION ALIGNMENT PROBLEM. MODELS AFFECTED: T5365A QUANTAR / QUANTRO EQUIPPED WITH MODEMS. SYSTEMS AFFECTED: ASTRO SIMULCAST ONLY 1.7, 3.0 CONVENTIONAL. SYMPTOM: During alignment, the Reference Modulation Compensation Alignment test pattern has low modulation, around 400 Hz deviation. CAUSE: Incorrect logic in the Quantar Conventional software. WORK AROUND: Before performing the Reference Modulation Alignment, 1) Read and archive the current codeplug configuration. 2) Change the Wireline Interface from MODEM to V.24 Only. 3) Program the station's codeplug with these changes, and reset the station. 4) Perform the Reference Modulation Compensation Alignment.
RESOLUTION: The Quantar software version 10.2, that fixes this issue will be available for purchase by the end of April 1999. NOTE: To purchase the updated software, contact your Motorola sales person. Software Subscription Agreement (SSA) subscribers should contact either their Motorola System Manager or System Integration (SI) specialist to order the software at no cost. This is an Informational Bulletin Only. No Reference to Warranty is Implied or Intended.
|