	<entry>
		<id>https://wiki.w9cr.net/index.php?title=Product_Support_Bulletin_922&amp;diff=4174&amp;oldid=prev</id>
		<title>Bryan: Created page with &quot; Category:Quantar Service Bulletin  &lt;html&gt; &lt;BODY&gt; &lt;P&gt;&lt;B&gt;COMMERCIAL GOVERNMENT &amp;amp; INDUSTRIAL SOLUTIONS SECTOR PSB # 922&lt;BR&gt;1301  E. ALGONQUIN RD.&amp;nbsp;&lt;BR&gt;SCHAUMBURG, IL...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.w9cr.net/index.php?title=Product_Support_Bulletin_922&amp;diff=4174&amp;oldid=prev"/>
		<updated>2019-03-28T09:57:28Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot; &lt;a href=&quot;/index.php/Category:Quantar_Service_Bulletin&quot; title=&quot;Category:Quantar Service Bulletin&quot;&gt;Category:Quantar Service Bulletin&lt;/a&gt;  &amp;lt;html&amp;gt; &amp;lt;BODY&amp;gt; &amp;lt;P&amp;gt;&amp;lt;B&amp;gt;COMMERCIAL GOVERNMENT &amp;amp; INDUSTRIAL SOLUTIONS SECTOR PSB # 922&amp;lt;BR&amp;gt;1301  E. ALGONQUIN RD. &amp;lt;BR&amp;gt;SCHAUMBURG, IL...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
[[Category:Quantar Service Bulletin]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;html&amp;gt;&lt;br /&gt;
&amp;lt;BODY&amp;gt;&lt;br /&gt;
&amp;lt;P&amp;gt;&amp;lt;B&amp;gt;COMMERCIAL GOVERNMENT &amp;amp;amp; INDUSTRIAL SOLUTIONS SECTOR PSB # 922&amp;lt;BR&amp;gt;1301 &lt;br /&gt;
E. ALGONQUIN RD.&amp;amp;nbsp;&amp;lt;BR&amp;gt;SCHAUMBURG, IL. 60196&amp;lt;BR&amp;gt;(847) 576-0180&amp;lt;/B&amp;gt;&amp;lt;/P&amp;gt;&lt;br /&gt;
&amp;lt;P&amp;gt;&amp;lt;B&amp;gt;APC # 148, 218, 225, 243, 301,&amp;amp;nbsp;&amp;lt;BR&amp;gt;&amp;amp;nbsp;360, 409, 448, 482, &lt;br /&gt;
509,&amp;amp;nbsp;&amp;lt;BR&amp;gt;&amp;amp;nbsp;537, 590, 675, 676, 677,&amp;amp;nbsp;&amp;lt;BR&amp;gt;680, &lt;br /&gt;
743,&amp;amp;nbsp;&amp;lt;BR&amp;gt;&amp;lt;/B&amp;gt;&amp;lt;/P&amp;gt;&lt;br /&gt;
&amp;lt;P align=left&amp;gt;&amp;lt;B&amp;gt;DATE: FEBRUARY, 2000&amp;lt;BR&amp;gt;EXPIRES: N/A&amp;lt;/B&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;B&amp;gt;&amp;lt;U&amp;gt;&amp;lt;/B&amp;gt;&lt;br /&gt;
&amp;lt;P&amp;gt;SUBJECT:&amp;lt;/U&amp;gt; QUANTAR/QUANTRO MAY NOT RECOVER UPON POWER INTERRUPTION OR POWER &lt;br /&gt;
LOSS&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;B&amp;gt;MODELS AFFECTED:&amp;lt;/B&amp;gt;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp; &lt;br /&gt;
QUANTAR / QUANTRO &lt;br /&gt;
(T5365A)&amp;lt;BR&amp;gt;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp; &lt;br /&gt;
QUANTAR SATELITTE RECEIVERS &lt;br /&gt;
(T5367A)&amp;amp;nbsp;&amp;lt;BR&amp;gt;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp; &lt;br /&gt;
ASTRO-TAC RECEIVERS &lt;br /&gt;
(T5589A)&amp;lt;BR&amp;gt;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp;&amp;amp;nbsp; &lt;br /&gt;
ASTRO-TAC COMPARATORS (T5770A)&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;B&amp;gt;SYSTEMS AFFECTED: &amp;lt;/B&amp;gt;ANY SYSTEM &lt;br /&gt;
CONTAINING QUANTAR/QUANTRO STATIONS WITH EPIC STATION CONTROL &lt;br /&gt;
MODULES.&amp;amp;nbsp;&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;B&amp;gt;STATION CONTROL MODULES &lt;br /&gt;
AFFECTED:&amp;amp;nbsp;&amp;lt;/B&amp;gt;&amp;lt;BR&amp;gt;CLN6686A, CLN6873A, CLN6960A, CLN6961A, TTN4093A-D, &lt;br /&gt;
TTN4094A-D, TRN7900A-C&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;B&amp;gt;SYMPTOM: &amp;lt;/B&amp;gt;Upon power interruption the &lt;br /&gt;
station may not recover and the Fail LED on the front of the Control Board will &lt;br /&gt;
be on.&amp;amp;nbsp;&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;B&amp;gt;CAUSE: &amp;lt;/B&amp;gt;Power loss or power interruptions as described &lt;br /&gt;
below may cause the above symptom.&amp;lt;BR&amp;gt;Please note this problem will not occur in &lt;br /&gt;
stations with emergency back up systems such as battery revert.&amp;lt;BR&amp;gt;1) A &lt;br /&gt;
momentary power loss that induces a power reset but does not fully discharge the &lt;br /&gt;
power supply for a sufficient length of time (approximately 5 seconds) could &lt;br /&gt;
cause the above symptom.&amp;lt;BR&amp;gt;2) Stations that are powered off for a sufficient &lt;br /&gt;
length of time (minute or more) but connected to externally powered peripherals &lt;br /&gt;
may also prevent a complete discharge of the power supply. A good example of &lt;br /&gt;
this would be an external high stability 5 Mhz reference.&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;In either case &lt;br /&gt;
these scenarios may not allow the PLL internal to the Host Microprocessor on the &lt;br /&gt;
board to start properly from a known state upon resetting. It may not be &lt;br /&gt;
possible to determine for certain if the cause of the lock-up is due to the &lt;br /&gt;
microprocessor state or some other influence such as invalid code plug version, &lt;br /&gt;
or firmware incompatibility. This particular problem will not be widespread. &lt;br /&gt;
However, isolated instances may occur.&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;B&amp;gt;RESOLUTION:&amp;lt;/B&amp;gt; To assure that &lt;br /&gt;
the PLL will start reliably it is recommended a jumper wire be added to the Host &lt;br /&gt;
Microprocessor (reference designator U401). A bottom side view, (solder side of &lt;br /&gt;
the Host Microprocessor U401) is included to aid in identifying the placement of &lt;br /&gt;
the jumper wire to be added. Looking at the bottom side of the Control Board, &lt;br /&gt;
orient the Control Board so that you can reference A1 to your lower left. In the &lt;br /&gt;
following drawing notice the pin identification rows and columns references ( &lt;br /&gt;
row A -T, columns 1-18 ).&amp;amp;nbsp;&amp;lt;BR&amp;gt;Add the jumper wire from ResetH ( row M - &lt;br /&gt;
column 18 ) to TRST ( row L - column 16 ). This will assure that TRST is &lt;br /&gt;
asserted during reset, also insuring the internal logic of the Host &lt;br /&gt;
microprocessor is restored to a known state upon reset.&amp;lt;/P&amp;gt;&lt;br /&gt;
&amp;lt;P align=center&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;SPAN &lt;br /&gt;
style=&amp;quot;FONT-FAMILY: 'Times New Roman'; FONT-SIZE: 10pt; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-language: EN-US; mso-bidi-language: AR-SA&amp;quot;&amp;gt;&amp;lt;IMG &lt;br /&gt;
height=596 src=&amp;quot;&amp;quot; width=560 v:shapes=&amp;quot;_x0000_i1025&amp;quot;&amp;gt;&amp;lt;/SPAN&amp;gt;&amp;lt;/P&amp;gt;&lt;br /&gt;
&amp;lt;P&amp;gt;&amp;lt;B&amp;gt;NOTE:&amp;lt;/B&amp;gt; If further assistance is required, contact the System Support &lt;br /&gt;
Center at 1-800-221-7144 and make reference to the bulletin &lt;br /&gt;
number.&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;&amp;lt;BR&amp;gt;This PSB is for informational Purposes Only.&amp;lt;BR&amp;gt;No Special &lt;br /&gt;
Reference to Warranty is implied or Intended. &amp;lt;BR&amp;gt;&amp;lt;/P&amp;gt;&amp;lt;/BODY&amp;gt;&amp;lt;/HTML&amp;gt;&lt;/div&gt;</summary>
		<author><name>Bryan</name></author>
		
	</entry>
</feed>