COMMERCIAL GOVERNMENT & INDUSTRIAL SOLUTIONS SECTOR

1301 E. ALGONQUIN RD.

SCHAUMBURG, IL. 60196

PSB # 908

APC # 218, 225, 301, 360, 409, 448, 482, 509, 537, 590, 675, 676, 743

(847) 576-0180

DATE: NOVEMBER, 1999

EXPIRES: N/A

SUBJECT: LOW POWER QUANTAR SHOWS DIAGNOSTIC ERRORS AFTER POWER ON SELF TEST AND REPORTS DIGITAL METERED VOLTAGES INCORRECTLY.

MODELS AFFECTED: T5365A QUANTAR/QUANTRO, T5367A QUANTAR RECEIVER

(Models Affected were built between 5/01/99 and 10/01/99)

SYSTEMS AFFECTED: CONVENTIONAL AND TRUNKING

SYMPTOM: During power up the Quantar RSS diagnostic test fails for incorrect digital meter readings of the 28V and 14V power supply. The RSS digital metering report are reported incorrectly as follows:

  • The 28Vdc reads 14.32V (approximately) and it should read N/A.
  • The 14Vdc reads 0.9V (approximately) and it should read 14.37V (approximately).
  • The 5V report reads correctly.

Please note, this is a diagnostic failure only, the 14V and 5V are correct, and this incorrect digital metering will not affect the operation of the station.

As a result of this issue, the following messages will appear in the Quantar RSS Status Report:

"EXECUTE_CONTINUOUS_DIAGNOSTICS PS_14V"

"EXECUTE_CONTINUOUS_DIAGNOSTICS PS_28V" These messages should be ignored.

CAUSE: The diagnostic circuits in the CPN1049B, and CPN1050B power supplies, built between 5/1/99 and 10/1/99, were assembled similar to the high power supply causing this abnormally in the voltage reading.

RESOLUTION: To prevent this diagnostic failure, the 14V and 28V Power Supply diagnostics can be disabled at Cold and Warm startup ( which will not affect the operation of the station ) by;

  • Connecting a PC equipped with the Quantar RSS to the Quantar, and starting the RSS application.
  • From the MAIN MENU, go to SERVICE: Diagnostics.
  • In the Power Supply diagnostics screen, tab to the COLD START, WARM START, and RUN NOW columns in the row, labeled PS 14V and PS 28V.
  • Press the space bar until the "X" indication disappears.

NOTE: In disabling the Power Supply diagnostics reports, the 14V and the 5V lines will be monitored by the Power Amplifier (PA) diagnostics report, and in case of a failure in either of these voltages, the PA diagnostics will report the failure (except the Quantar receiver, no PA diagnostics).

This is an Informational Bulletin Only.

No reference to Warranty is Implied or Intended.

Serial Numbers of Stations Affected

Quantar Analog

Quantar Astro Conventional

Quantar SmartZone Astro IntelliRepeater

448CZM0047

509CZR0006

537CZT0026

448CZM0048

509CZT0010

537CZT0027

448CZM0049

509CZT0011

537CZT0028

448CZM0050

509CZT0012

537CZT0029

448CZM0051

509CZT0013

537CZT0030

448CZM0133

537CZT0031

448CZM0220

537CZT0032

448CZP0080

537CZT0033

448CZP0081

537CZT0034

448CZP0125

537CZT0035

448CZP0166

448CZP0167

Data Base Station

448CZT0051

680CZR0016

448CZT0125

680CZT0000

Quantar SmartZone IntelliRepeater

Analog Receiver

675CZM0042

677CZM0004

675CZM0043

677CZM0005

675CZM0044

677CZM0010

675CZM0045

677CZM0011

675CZM0046

677CZM0012 thru 677CZM0014

675CZM0047

677CZM0047 thru 677CZM0060

677CZM0154 thru 677CZM0159

677CZM0315 thru 677CZM0322

677CZM0326 thru 677CZM0328

677CZM0365 thru 677CZM0369

677CZP0001 thru 677CZP0056

677CZR0073

677CZT0000

677CZT0001

677CZT0026

Serial Numbers of Field Replacement Units (FRU) Affected

CAEUW20GC6

CAEYU60RZT

CAEYU60RZV

CAEYU60RZW

CAEYU60S4R

CAEYU60S4S

CAEYU60S5J

CAEYU60S5K