BULLETIN MOTOROLA PRODUCT SERVICES

LAND MOBILE PRODUCT SECTOR PSB # 747 1307 E. ALGONQUIN RD APC # 509 SCHAUMBURG, ILL. 60196 EXPIRATION Date: N/A (708) 576-0180

Subject: QUANTAR POWER AMPLIFIERS

MODELS AFFECTED: ALL QUANTAR RADIOS VHF, 800, 900 MHZ

When making any repairs to the below listed Power Amplifiers, especially when any PA modules are replaced, it is highly recommended that the servicing technician check the resistance of the circulator load TTN5238A for 50 ohms resistance.

To check the load's resistance, remove the Omega Strap to the load module and check the resistance with an Ohmmeter for a value of 50 ohms. If the circulator load has failed, the Final or Driver PA module may have been damaged. If the circulator load needs replacing, the PA deck should be retested to insure proper performance.

Power Amplifier Kits Involved:

TLD-3110A QUANTAR-- 25 WATT--VHF TLD-3101A QUANTAR--125 WATT--VHF TLD-3102A QUANTAR--125 WATT--VHF TLF-1930A QUANTAR--100 WATT--800 MHZ TLF-1800A QUANTAR--100 WATT--900 MHZ